An unsatisfactory EICR isn’t a fine or a failed exam. It starts a clock. For landlords in England the rules set out what must be fixed, by when, and who has to be told.
What makes a report unsatisfactory
Any finding coded C1 (danger present), C2 (potentially dangerous) or FI (further investigation) makes the overall result unsatisfactory. Findings coded C3 on their own do not. See our guide to the codes for what each one means.
The 28-day clock
- Get the remedial or further investigation work done within 28 days of the inspection, or the shorter period written on the report.
- The work must be done by a qualified person.
- Send written confirmation that the work is done to the tenant and the local council within 28 days of finishing it.
C1: made safe now
Danger present means it can’t wait for a quote. Most inspectors will make it safe or isolate it with your agreement before leaving, and tell you and the occupier. The permanent repair follows.
What counts as written confirmation
A new satisfactory EICR, an Electrical Installation Certificate, or a Minor Works certificate from the person who did the repair. GOV.UK guidance lists all three.
Some repairs need Part P sign-off
In England, a new circuit, a replacement consumer unit or a rewire is notifiable building work. A registered installer self-certifies it; otherwise building control must be involved.
You don’t have to use the same electrician
You can get the repairs quoted by any qualified electrician, or get a second opinion. We quote repairs separately, after the report, and never as a condition of the inspection.
Copies, and what’s at stake
- Existing tenants get a copy of the report within 28 days of the inspection.
- New tenants get one before they move in.
- The council gets one within 7 days if it asks.
- Keep the report until the next inspection and give a copy to the next inspector.
Since the 2025 amendment, the maximum civil penalty is £40,000 per breach.